Technical Specifications
Technical Specs
Download brochure
Download Diagrams
Size:
- Many size options are available; can accommodate anything from a solo musician to a large group, band or choir.
- Typical internal ceiling height is 2300mm.
Performance:
- Typical sound insulation performance;
- Room to corridor would be circa DnT,w41dB, Room to room would be circa DnT,w54dB.
- Third octave band sound transmission losses available on request, tested in accordance with ISO 140/4.
Flexibility:
- Modular panel design provides a large selection of different size rooms.
- Easy re location or size adjustment of existing rooms.
Construction:
- Modular 100mm thick panels are secured with full length ‘C’ or ‘L’ clip fixings.
- Acoustically sealed base channel controls wall panel placement. Neoprene seals to the base of all MPR walls assist regarding the elimination of structure borne sound transfer.
- Panel comprises of 1mm gauge solid steel outer skin and 0.7mm gauge perforated steel inner skin.
- Powder coated panel finish; Light grey outer/satin white inner.
- Ceiling panels are secured using an interlocking tongue & groove jointing arrangement.
- Typical panel weight would be nominally 32kgs/m2.
- Solid skin internal surfaces exist at all corner, power panel and inlet/extract ventilation panel locations.
- Single leaf personnel acoustic engineered door has ¾ length, centrally located vision panel, locking hardware and thumb turn override. Steel construction with acoustic seals. Shallow 33mm threshold can be negotiated for wheelchair access.
- Glazed acoustically engineered windows are available, for control room purposes, observation, security or to provide natural light.
Ventilation:
- Integral fan unit and external vertical attenuated tract for extract air and external attenuated vertical duct for inlet air.
- Nominally 4No air changes per hour will be achieved using a scavenge ventilation system, on the basis of providing 8 litres/sec per individual (room size dependent).
- Acoustically isolated HVAC connections are also available.
Lighting:
- Surface fixed lighting would comprise high frequency florescent unit/s, controllable from wall mounted switching via RCD.
Electrical Components:
- No double socket, internal RCD with control switching on vertical trunking(as standard).
- Additional sockets, data points etc are available within 3 compartment dado trunking.
- Wiring to the associated internal services and external isolator etc would be by others.
- All components are CE certified and comply with BSEN 9002 European wide directive.
- Minimum clearance over room height to be a minimum of 150mm.
- Minimum spacing of 50mm from walls and 250mm from adjacent MPR’s.
- Supporting floor structures will accommodate the room loadings, be flat level and true.
- Floor level tolerance provides a minimum flat and level surface of 3mm over 1000mm.
- Ventilation of the room where the MPR is located is required.
- Wiring to and from internal services to external isolators will be undertaken by others.
- Installation service (if required) demands room to be cleared of furniture prior to the arrival of our installation team.
- Site inspection carried out, by our Acoustic Engineer and acoustically trained staff, before delivery/installation schedule is agreed.
Options and additions:
- Closure panels between and around MPR’s.
- Sound isolating floating floors available.
- Glazed acoustically engineered windows available, for control room purposes, observation, security or to provide natural light.
- Additional sockets, data points etc are available within 3 compartment dado trunking.
- Sound limiting devices available for fitting in accordance with BB93 and/or Health and Safety requirements.
Technical Specs
Download brochure
Download Diagrams
Contact us for a Quote
|




|